Identity and sessions¶
Two props identify where an event came from: hostMachineId, which is meant
to be stable for the life of a machine, and sessionId, which is minted per
run. What can be joined to what follows entirely from how those two are
produced, and the answer is not the same on Windows and macOS.
sessionId¶
A fresh GUID, minted once per producer process and never changed:
| producer | minted in | covers |
|---|---|---|
| the plug-in | SEAnalyticsEventsManager's constructor, early in SEMain::Initialize() |
one OBS run |
| the installer | scienceInit, from .onInit |
one installer run |
| the uninstaller | scienceInit, from .onInit |
one uninstaller run |
So a plug-in sessionId is an OBS session, and a restart of OBS is a new
one. It is not a user, an account or an install.
The plug-in's value is also handed to pages: ISEHostInfoProvider reports
it as hostSessionUniqueId alongside hostMachineUniqueId from the same
manager (SEHostInfoProvider.cpp:34), which is how a page can tie its own
telemetry to an analytics session.
hostMachineId on Windows¶
One value, cached in the registry, minted by whichever SE program needed it first:
HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\StreamElements
MachineUniqueIdentifier REG_SZ
The 64-bit plug-in spells WOW6432Node explicitly
(SEUtils/SEEnvConfigUtils.cpp:38). The installer and uninstaller are
32-bit processes asking for SOFTWARE\StreamElements, which WOW64 redirects
to the same key. So all three producers read and write one value, and
hostMachineId is directly comparable across them.
Every id is <4-letter tag>/<payload>, and the tag says which code minted
it:
| tag | minted by | payload |
|---|---|---|
WUID/ |
the NSIS helper | a machine UUID |
SWID/ |
the plug-in | the WMI Win32_ComputerSystemProduct UUID, a GUID and a crypto-random string |
SEID/ |
either, when no machine UUID could be read | a GUID and a crypto-random string |
The plug-in's own generation path is at
SEUtils/SESystemInfoUtils.cpp:633: read the registry, and only if that
yields nothing usable, query WMI for the product UUID (SWID/), falling
back to a generated id (SEID/). On a normal Windows install the installer
has already run and written the value, so the plug-in only ever reads it —
which is why a WUID/ id is the common case in the data even though the
plug-in cannot produce one.
The NSIS side is not readable as source here
NSISConfig.dll is fetched from
cdn.streamelements.com/obs/dist/nsis-config at installer build time,
so the table above is read off the strings embedded in the shipped DLL
— SOFTWARE\StreamElements, MachineUniqueIdentifier, WUID/,
SEID/ and the same select * from Win32_ComputerSystemProduct query
— plus the plug-in source that reads the result. The algorithm matches;
the code is elsewhere.
Values the plug-in refuses¶
A stored id is read back and then validated, because it is written straight
back out again and so becomes that machine's permanent identity. Four exact
strings are rejected as known-bad — a known duplicate, all-zeroes,
all-Fs, and one value set by a cracked Office installer — and so is
anything not even shaped like an id: shorter than 16 characters, or without
a / at index 4.
That second rule exists because of an observed machine whose stored id was
literally "S", the first character of an SWID/SEID value. Every crash
report from it was anonymous and none could be correlated with any other. A
rejected value is logged at LOG_WARNING and a fresh id is generated on the
spot.
The id can change between sessions if the write fails¶
The write is to HKEY_LOCAL_MACHINE, so it needs elevation. When the direct
write fails, WriteEnvironmentConfigStrings falls back to
ShellExecuteW(..., "runas", "obs-streamelements-set-machine-config.exe", ...)
— a UAC prompt. If that is declined, or the helper is missing, nothing is
persisted and the next process to need an id mints another one.
Within one OBS session this does not show up in the data: the analytics
manager reads the id once, in its constructor, and every event uses that
cached copy. Across sessions it does — the same machine reports a different
hostMachineId each run. So hostMachineId is a reliable machine key only
where the value was successfully persisted, which is the normal case
precisely because the installer runs elevated and writes it first.
hostMachineId on macOS¶
A different scheme, in SEUtils.mm:80:
ALSU/<IOPlatformSerialNumber>-<uppercase SHA-256 of the login name>
Two consequences worth keeping straight:
- It is per user, not per machine. The username hash is part of the id,
so two macOS accounts on one Mac are two
hostMachineIdvalues. The Windows id has no user component at all. - There is no registry and no persistence. It is derived from the
hardware serial on every call, so it is stable without needing to be
written anywhere — and the failure modes are the literal sentinel strings
ERR_NO_PLATFORM_EXPERT,ERR_NO_CFS_SERIALandERR_NO_NS_SERIAL, which reach the wire as thehostMachineIdvalue itself. Those three strings in the data are a machine whose serial could not be read, not an id.
There is no macOS installer or uninstaller in this repository, so on macOS the plug-in is the only producer and the cross-producer join below does not arise.
What joins to what¶
| question | key | works? |
|---|---|---|
| which events belong to one OBS run | sessionId |
yes |
| which events belong to one installer run | sessionId |
yes |
| did this machine install and then run SE.Live | hostMachineId |
yes, on Windows |
| did this machine install and then uninstall | hostMachineId |
yes, on Windows |
| which install produced this OBS session | — | no |
| which user | — | no |
The fifth row is the one that catches people. The installer and the plug-in
share a machine id but nothing narrower: their sessionIds are independent,
and no event carries the other producer's session. An install and a
subsequent first run can be ordered by timestamp on the same machine, but
they cannot be linked as one flow.
The sixth row is by design: nothing in any payload identifies a
StreamElements account, a channel or a person. The plug-in knows the signed-in
state (ISEConfig::STARTUP_FLAGS_SIGNED_IN) and does not report it.
Where the identity leaves the payload¶
Once, in the uninstaller. ShowFarewellPopup
(CI/obs-streamelements-uninstaller/main.nsi:635) opens the uninstall
survey in the user's browser with both ids appended as query parameters:
https://obs.streamelements.com/uninstall-popup-quiz?identity=<hostMachineId>&session=<sessionId>
The URL is overridable through the UninstallerPopupQuizUrl product
environment value, and the parameters are appended either way. This is the
one place either id travels anywhere other than the analytics endpoint, and
it is what lets a survey answer be joined to the uninstall events that
preceded it.
What else is personal¶
Two payloads carry user-authored or user-specific text, both from the plug-in, and both are worth knowing before treating the event stream as anonymous:
se_live_report_issueputs the user's own description of their problem in themessageprop — free text, typed by the user, whatever they chose to write in it.se_live_dock_show_click/se_live_dock_hide_clickcarry the dock's live window title indock_widget_title, which for a user-added dock is a name the user or a page chose.
Nothing else in the catalogue contains a path, a hostname, an account, a URL or a machine name.
Related¶
- The envelope — where these two props sit.
- Plug-in events — the two events named above.
- Uninstaller events — the farewell popup in context.